Formed 4A / 4B Systems


WHAT IS FORM ?
While applying the form separation process, metal or non-metal parts are used in order to prevent the transition between the sections. With using these parts, direct access of the user to live parts or materials such as circuit breakers is prevented. In practice, when the door is opened, we should not encounter an energized busbar. For the reliability of the compartments, they should be opened using a hand tool such as a key. In addition, the holes on the parts for which separation is provided must be large enough not to pass fingers.,

FORM 4B SYSTEMS
Separation of busbars and functional units, as well as the separation of functional units within themselves. In addition, external conductor terminals must also be separated from functional units, and external conductor connection points must be separated among themselves. External conductor connection points must be in a separate compartment.
Form 4A : The supply terminals of the functional units and the external conductor terminals are inseparable. External conductor terminals are separated among themselves
Form 4B : The supply terminals of the functional units and the external conductor terminals are separated from each other. External conductor terminals are separated among themselves.

Center Office & Showroom

Bankalar Cad. Yanıkkapı Porsuk Sok.
Köse Han No 2/1 Karaköy / İstanbul



yavuzpano@yavuzpano.com.tr


T : +90 212 254 39 21
F : +90 212 254 39 64
Kocaeli Factory

Cumhuriyet Mah. Selin Sok. No : 3
Çayırova/Gebze/Kocaeli/TÜRKİYE



yavuzpano@yavuzpano.com.tr


T : +90 262 658 15 11 Pbx
F : +90 262 658 15 12
Follow Me

Do not forget to follow us on Social Media to be informed about the latest developments about us.

All Rights Reserved YAVUZ Pano Aydınlatma © 2020
Formed 4A / 4B Systems

WHAT IS FORM ?
While applying the form separation process, metal or non-metal parts are used in order to prevent the transition between the sections. With using these parts, direct access of the user to live parts or materials such as circuit breakers is prevented. In practice, when the door is opened, we should not encounter an energized busbar. For the reliability of the compartments, they should be opened using a hand tool such as a key. In addition, the holes on the parts for which separation is provided must be large enough not to pass fingers.,

FORM 4B SYSTEMS
Separation of busbars and functional units, as well as the separation of functional units within themselves. In addition, external conductor terminals must also be separated from functional units, and external conductor connection points must be separated among themselves. External conductor connection points must be in a separate compartment.
Form 4A : The supply terminals of the functional units and the external conductor terminals are inseparable. External conductor terminals are separated among themselves
Form 4B : The supply terminals of the functional units and the external conductor terminals are separated from each other. External conductor terminals are separated among themselves.



Center Office & Showroom

Bankalar Cad. Yanıkkapı Porsuk Sok.
Köse Han No 2/1 Karaköy / İstanbul


yavuzpano@yavuzpano.com.tr


T : +90 212 254 39 21
F : +90 212 254 39 64
Kocaeli Fabrika

Cumhuriyet Mah. Selin Sok. No : 3
Çayırova/Gebze/Kocaeli/TÜRKİYE


yavuzpano@yavuzpano.com.tr


T : +90 262 658 15 11 Pbx
F : +90 262 658 15 12
Follow Me

Do not forget to follow us on Social Media to be informed about the latest developments about us.

All Rights Reserved YAVUZ Pano Aydınlatma © 2020