MCC Formed Systems




360 DEGREE VIEW

PRODUCT SPECIFICATIONS

Frame : TT Series (Galvanized) 2 mm Steel
Construction : Moduler Without Weld
Door : 2 mm Mild Steel
Side Cover : 1,2 mm Mild Steel
Back Cover : 1,2 mm Mild Steel
Foam Systems : Polyurethane Foam Gasket
Hinges : Four Point Secret Hinges
Base Structure : Plastic Leg + Base closing
Paint : RAL 7035 Electrostatic Powder Paint
IP Protection : IP41 / IP54
IK Impact Resistance : IK10


Product Details Technical Documents Internal Parts
Vertical Without Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B / 4B standards, but also protection cover is needed. Applicable Current Values 32A-250A Material: 1,5mm Galvanized
Vertical Without Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B / 4B standards, but also protection cover is needed. Applicable Current Values 400A-630A Material: 2 mm Galvanized
Vertical Without Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B / 4B standards, but also protection cover is needed. Applicable Current Values 800A-1250A Material: 2 mm Galvanized
Horizontal With Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B standards. Applicable Current Values 32A-250A Material: 1,5mm Galvanized
400A-630A Horizontal With Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B standards. Applicable Current Values 400A-630A Material: 2 mm Galvanized
800A-1250A Horizontal With Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B standards. Applicable Current Values 800A-1250A Material: 2 mm Galvanized
Main Busbar Front and Back Cover
It covers front and back access to main busbar. Dimensions of covers changing depends on board and busbar widths. Material: 1 mm Galvanized
Main Busbar Bottom and Top Cover
It covers bottom and top access to main busbar. Dimensions of covers changing depends on board width and depth. Material: 1 mm Galvanized
Main Busbar Right and Left Cover
It covers right and left access to main busbar. Dimensions of covers changing depends on board depth and busbar width. Material: 1mm Galvanized, 2mm PC Glass
Inner Mounting Plate
Mounting plate for motor circuit equipment. Applicable Power Range 0,15-25kW Material: 1,5 mm GalvanizedMotor devre ekipmanlarına alt ve üstten ulaşımı engeller ve bölümlendirilir. Pano genişliği ve derinliğine göre ölçüleri değişir. Mataryel: 1 mm Galveniz
Inner Mounting Plate’s Bottom and Top Cover
Covers prevent access to motor circuit equipment from bottom and top. Dimensions are changing according to board width and depth. Material: 1 mm Galvanized
Inner Mounting Plate
Mounting plate for motor circuit equipment. Applicable Power Range 25-40kW Material: 1,5 mm Galvanized
Inner Mounting Plate’s Bottom and Top Cover
Covers prevent access to motor circuit equipment from bottom and top. Dimensions are changing according to board width and depth. Material: 1 mm Galvanized
Inner Mounting Plate for Variable Speed Driver
Mounting plate for variable speed driver. There must be hole to assembly driver. Hole dimensions are changing according to driver’s size. Material: 2 mm Galvanized
3B Terminal Cell
It is the external conductor connection point. It conforms to Form 3B standards thanks to its separation from functional units and busbars. Material: 1 mm Galvanized
4B Terminal Cell
It conforms to Form 4B standards thanks to its separation from functional units and busbars also separation of functional units within themselves. Material: 1 mm Galvanized
Vertical Busbar Cell
It separates between main busbar and MCCB inputs because of vertical busbar cell.
Center Office & Showroom

Bankalar Cad. Yanıkkapı Porsuk Sok.
Köse Han No 2/1 Karaköy / İstanbul



yavuzpano@yavuzpano.com.tr


T : +90 212 254 39 21
F : +90 212 254 39 64
Kocaeli Factory

Cumhuriyet Mah. Selin Sok. No : 3
Çayırova/Gebze/Kocaeli/TÜRKİYE



yavuzpano@yavuzpano.com.tr


T : +90 262 658 15 11 Pbx
F : +90 262 658 15 12
Follow Me

Do not forget to follow us on Social Media to be informed about the latest developments about us.

All Rights Reserved YAVUZ Pano Aydınlatma © 2020
MCC Formed Systems




360 DEGREE VIEW

Frame
TT Series (Galvanized) 2 mm Steel
Construction
Moduler Without Weld
Door
2 mm Mild Steel
Side Cover
1,2 mm Mild Steel
Back Cover
1,2 mm Mild Steel
Foam Systems
Polyurethane Foam Gasket
Hinges
Four Point Secret Hinges
Base Structure
Plastic Leg + Base closing
Paint
RAL 7035 Electrostatic Powder Paint
IP Protection
IP41 / IP54
IK Impact Resistance
IK10

Product Features



Vertical Without Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B / 4B standards, but also protection cover is needed. Applicable Current Values 32A-250A Material: 1,5mm Galvanized


Vertical Without Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B / 4B standards, but also protection cover is needed. Applicable Current Values 400A-630A Material: 2 mm Galvanized


Vertical Without Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B / 4B standards, but also protection cover is needed. Applicable Current Values 800A-1250A Material: 2 mm Galvanized


Horizontal With Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B standards. Applicable Current Values 32A-250A Material: 1,5mm Galvanized


400A-630A Horizontal With Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B standards. Applicable Current Values 400A-630A Material: 2 mm Galvanized


800A-1250A Horizontal With Socket Fixed MCCB Panel
With panel design that prevents access to the busbar, it complies with Form 3B standards. Applicable Current Values 800A-1250A Material: 2 mm Galvanized


Main Busbar Front and Back Cover
It covers front and back access to main busbar. Dimensions of covers changing depends on board and busbar widths. Material: 1 mm Galvanized


Main Busbar Bottom and Top Cover
It covers bottom and top access to main busbar. Dimensions of covers changing depends on board width and depth. Material: 1 mm Galvanized


Main Busbar Right and Left Cover
It covers right and left access to main busbar. Dimensions of covers changing depends on board depth and busbar width. Material: 1mm Galvanized, 2mm PC Glass


Inner Mounting Plate
Mounting plate for motor circuit equipment. Applicable Power Range 0,15-25kW Material: 1,5 mm GalvanizedMotor devre ekipmanlarına alt ve üstten ulaşımı engeller ve bölümlendirilir. Pano genişliği ve derinliğine göre ölçüleri değişir. Mataryel: 1 mm Galveniz


Inner Mounting Plate’s Bottom and Top Cover
Covers prevent access to motor circuit equipment from bottom and top. Dimensions are changing according to board width and depth. Material: 1 mm Galvanized


Inner Mounting Plate
Mounting plate for motor circuit equipment. Applicable Power Range 25-40kW Material: 1,5 mm Galvanized


Inner Mounting Plate’s Bottom and Top Cover
Covers prevent access to motor circuit equipment from bottom and top. Dimensions are changing according to board width and depth. Material: 1 mm Galvanized


Inner Mounting Plate for Variable Speed Driver
Mounting plate for variable speed driver. There must be hole to assembly driver. Hole dimensions are changing according to driver’s size. Material: 2 mm Galvanized


3B Terminal Cell
It is the external conductor connection point. It conforms to Form 3B standards thanks to its separation from functional units and busbars. Material: 1 mm Galvanized


4B Terminal Cell
It conforms to Form 4B standards thanks to its separation from functional units and busbars also separation of functional units within themselves. Material: 1 mm Galvanized


Vertical Busbar Cell
It separates between main busbar and MCCB inputs because of vertical busbar cell.


Technical Documents



Internal Parts

Center Office & Showroom

Bankalar Cad. Yanıkkapı Porsuk Sok.
Köse Han No 2/1 Karaköy / İstanbul


yavuzpano@yavuzpano.com.tr


T : +90 212 254 39 21
F : +90 212 254 39 64
Kocaeli Fabrika

Cumhuriyet Mah. Selin Sok. No : 3
Çayırova/Gebze/Kocaeli/TÜRKİYE


yavuzpano@yavuzpano.com.tr


T : +90 262 658 15 11 Pbx
F : +90 262 658 15 12
Follow Me

Do not forget to follow us on Social Media to be informed about the latest developments about us.

All Rights Reserved YAVUZ Pano Aydınlatma © 2020